← Standards & Specs

The Toolbox — Standards

Electrical

Electrical system standards and LiPo battery safety specifications.

Electrical Standards

SpecificationValue / Notes
US household voltage120V AC RMS / 240V AC RMS (split phase)
US power frequency60 Hz
Aircraft DC standard (most commercial)28V DC
Aircraft AC standard (most commercial)115V AC, 400 Hz, 3-phase
Marine 12V system nominal12.6V (fully charged) / 11.8V (50% discharged)
Marine 24V system nominal25.2V (fully charged) / 23.6V (50% discharged)
Maximum recommended voltage drop (DC wiring)3% of system voltage
Maximum recommended voltage drop (critical loads)1% of system voltage
GFI trip threshold5 milliamps imbalance
GFI trip timeLess than 1/40 second (25 ms)
AWG 12 max ampacity (chassis wiring)20 amperes
AWG 14 max ampacity (chassis wiring)15 amperes
AWG 16 max ampacity (chassis wiring)13 amperes
Recommended wire fill (conduit)40% maximum cross-sectional area

LiPo Battery Safety Standards

SpecificationValue / Notes
Cell nominal voltage3.7V per cell
Cell fully charged voltage4.2V per cell (standard) / 4.35V (HV LiPo)
Cell storage voltage3.8V – 3.85V per cell
Cell minimum safe voltage3.0V per cell — do not discharge below
Cell critical low voltage3.5V per cell — land immediately
C rating definitionMaximum continuous current = C rating × capacity in Ah
Charging rate (standard)1C maximum for longevity
Charging rate (fast charge)Up to 5C for supported packs — reduces lifespan
Operating temperature range0°C to 45°C — performance degrades below 10°C
Fire risk temperatureThermal runaway begins above approximately 70°C
Charging supervisionNever leave LiPo charging unattended
Internal resistance — new packBelow 5 mΩ per cell
Internal resistance — retirement thresholdAbove 20 mΩ per cell — retire from flight use